Hi All,

This will be the last report from me. Calibration activities have started and somebody else will be reporting on these.

Observing:
----------

121104 04:56:28 - 121106 00:40:01
    * 9_CMB_36c_dk293_016.sch
    * Aborted to mount FFFlat
    * bicep33 rebooted and GCP & masd restarted after schedule

121104 04:38:59 - 121104 04:40:23
    * mce_autotune.sch
    * MASD restart, DSP driver reload & mce_reset_clean, GCP restart after running schedule.

121104 01:35:57 - 121104 01:44:13
    * starpoint_pole_bicep_summer.sch
    * Not clear enough for an actual pointing. Just showing Chin Lin how to run a pointing schedule

121103 22:54:09 - 121103 22:59:46
    * do_cycle.sch
    * Tilts:
    az    0°    180°
    x    -9.157    -9.377
    y    9.371    10.833
    * dk=0
    * cleaned GS, boot, UFB, window
    * Membrane 0.15/0.5

121101 04:33:54 - 121103 22:54:09
    * 8_CMBdark_36a_dk068_004.sch

121101 04:20:58 - 121101 04:22:23
    * mce_autotune.sch
    * MASD restart, DSP driver reload & mce_reset_clean, GCP restart after running schedule.

121031 23:03:43 - 121031 23:09:19
    * do_cycle.sch
    * Tilts:
    az    0°    180°
    x    -9.025    -9.256
    y    9.602    10.448

121031 23:02:54 - 121031 23:03:41
    * do_cycle.sch
    * Fridge cycle client died.

121031 22:42:27 - 121031 23:02:54
    * 8_NTD_crosstalk_v2_002.sch

121031 22:21:58 - 121031 22:42:27
    * 8_NTD_crosstalk_v2_001.sch

121029 05:55:31 - 121031 22:15:25
    * 9_CMB_36c_dk248_016.sch
    * Aborted in last scan set


Telescope:
----------
- Ran NTD x-talk v2 schedule twice
- Ran CMBdark schedule
- Stopped CMB obs to mount FFFlat

Weather
--------
- Mostly good, clouds and overcast periods prevented pointing schedules during the fridge cycles

Cryogenics:
-----------

* Tracking spreadsheet at http://bicep.rc.fas.harvard.edu/bicep2/south_pole_helium_usage/Summer_2011_Winter_2012_NPX_Cryo_Tracking.xls

* Flint is here

* I investigated the much higher than usual vent gas recapture rates in the previous two transfers. Found that Kathleen didn't completely close the valve on tank 5. Pressure was slowly equalizing between tanks 5 and 8. Measured contamination in 5, 6, 7, and 8 and they appear clean. Flint will just have to top up tank 5 once we are done with 8.

* Kathleen's Cryo Sitrep:

LHe:

 

 

 

 

 

 

GHe:

 

 

LN2:


Analysis/software/computers:
----------------------------
- Firewall crashed again today. Second time now. Will investigate.

Cheers,
       Steffen